Cylindrical cell (12A)

Cylindrical cell (12A)



Battery cell parameters

project parameter remark
Rated capacity 12Ah discharged at 0.5C (25±3)℃, 0.5C constant current discharge, voltage range 2.5V ~4.25V
Rated voltage 3.60V  
Standard charging  Standard charging current 0.5C Constant voltage segment cut-off current 0.05C
  Standard charging voltage 4.25V  
Standard discharge Standard discharge current 0.5C  
  Standard discharge voltage 2.5V  
Maximum charging current 1C The maximum charging current should not exceed 1C within the temperature range of 15-45℃
Maximum discharge current 2C  
  10C 30s
  Operating Temperature charge   -20~60℃ -20℃≤T≤-5℃, charging current ≤0.1C-5℃≤T≤15℃: Charging current ≤0.2C; 15℃≤T≤45℃: Charging current ≤1C45℃≤T≤60℃, charging current ≤0.5C
  discharge -40~60℃ Discharge cut-off voltage: 2.5V for 0℃
Storage temperature 0~45℃  
Initial AC impedance ≤2 mΩ 40~50% SOC state
Battery cell quality 290±5g  
appearance No cracks, scratches, deformations, stains, electrolyte leakage, etc
 size (33.2±0.2)mm*(140±0.3)mm  For details, see Appendix 10


download


Cylindrical -12A Battery Cell Product Specification